8.2 Film type selection
Most procedures and codes of good practice for the performance of industrial radiography
base the choice of type of film for a specific application on the EN or ASTM classification
systems. For weld inspection, when one is attempting to detect small cracks, a film of class
C2 or C3 would be specified. For the examination of castings or general radiography a film
of class C4 or C5 would normally be used. For small component inspection, where the
image might be viewed under magnification to reveal small details, a film of class C2 or
possibly even a single emulsion film of class C1 would be desirable.
In megavoltage radiography, because most equipment have a very high radiation output,
class C3 films can be used for objects of great wall thickness. This has the advantage that a
high film gradient can be achieved.
8.3 Film sizes
Film sizes in industrial radiography are to a large extent standardised according to
ISO 5565. Non-standard sizes are possible. Standard film sizes and metal screens are
supplied separately, but can also be supplied vacuum-packed so that the risk of film faults
is considerably reduced. For weld inspection there is so-called Rollpac film strip on the
market which is available on a roll together with the lead screen. For very large projects the
strip film can even be pre-cut to suit a particular weld length or pipe/vessel circumference.
8.4 Handling and storage of unexposed films
The conditions under which unexposed films are handled and stored play a very important
role in the final quality of the exposed film. Recommendations for handling and storage
are contained in, for example, ASTM E1254. “Pre-exposure” as a result of background radi-
ation must be avoided as it causes unacceptable fogging of the film.
If films are to be kept for a longer period, the following storage conditions must be
adhered to:
background radiation levels below 90 nGray
temperatures below 24˚C
relative humidity levels below 60 %
away from X-ray film chemicals
preferably stacked on edge
In the long run, minor fogging will occur to films stored. Background fog to a maximum
density of 0.3 is considered acceptable.