Installation Instructions
11
14
BATHROOM OR BEDROOM INSTALLATION
• The appliance MUST be vented to the outdoors. See
EXHAUST INFORMATIONVHFWLRQ
• The installation must conform with local codes or,
in the absence of local codes, with the NATIONAL
ELECTRICAL CODE, ANSI/NFPA NO. 70 and
NATIONAL
FUEL GAS CODE, ANSI Z223.
12
MOBILE OR MANUFACTURED HOME
INSTALLATION
• Installation MUST conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard is not
applicable, with AMERICAN NATIONAL STANDARD
FOR MOBILE HOME, ANSI/NFPA NO. 501B.
• The appliance MUST be vented to the outdoors with
the termination securely fastened to the mobile home
structure.
• The vent MUST NOT be terminated beneath a mobile or
manufactured home.
• The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the appliance
securely to the structure.
• The vent MUST NOT be connected to any other duct, vent, or
chimney.
• Do not use sheet metal screws or other fastening
devices which extend into the interior of the exhaust
vent.
• Provide an opening with a free area of at least 25 sq. in. for
introduction of outside air into the dryer room.
13
ALCOVE OR CLOSET INSTALLATION
• If your appliance is approved for installation in an alcove
or closet, it will be stated on a label on the appliance
back.
• The dryer MUST be vented to the outdoors. See the EXHAUST
INFORMATION section.
• Do not install this appliance with less than the minimum
clearances shown above.
• The closet should be vented to the outdoors to prevent gas
pocketing in case of a gas leak in the supply line.
• No other fuel-burning appliance shall be installed in the same
closet with the appliance.
CONSIDERATION MUST BE GIVEN TO PROVIDE
ADEQUATE CLEARANCES FOR INSTALLATION
AND SERVICE.
WARNING: DO NOT INSTALL THIS
APPLIANCE IN A CLOSET WITH A SOLID DOOR.
1”
0”
0”
0”
1”
DOOR VENTILATION OPENING (27”
MODELS)
A minimum of 120 square inches of opening, equally
divided at top and bottom, is required. Air openings are
required to be unobstructed when a door is installed. A
louvered door with equivalent air openings for the full
length of the door is acceptable.
When louvers or registers are placed in door openings,
the free air openings of the louvers or registers must
equal 120 square inches.
DOOR VENTILATION OPENING (24”
MODELS)
A minimum of 72 square inches of opening is required. Air
openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for
the full length of the door is acceptable.
When louvers or registers are placed in door openings,
the free air openings of the louvers or registers must
equal 72 square inches.
6T,Q
6T,Q
27” Model
48 Sq. In.
24 Sq. In.
24” Model