GE GUD24GSSJWW Manuale delle Istruzioni

Navigare online o scaricare Manuale delle Istruzioni per Asciugatrici elettriche GE GUD24GSSJWW. GE GUD24GSSJWW Instructions / Assembly Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 36
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
EXHAUST HOOD
FLEXIBLE GAS LINE CONNECTOR
SOAP SOLUTION
FOR LEAK DETECTION
PIPE
COMPOUND
DUCT TAPE
GLOVES
SAFETY GLASSES
4" DIAM METAL ELBOW
4" DUCT CLAMPS
OR
4" SPRING CLAMPS
(x2)
(x2)
4" DIA. FLEXIBLE METAL (SEMI-RIGID)
UL LISTED TRANSITION DUCT
(IF NEEDED)
KIT WX08X10077 (INCLUDES 2 ELBOWS)
4" DIA. METAL DUCT
(RECOMMENDED)
4" DIA. FLEXIBLE METAL (FOIL TYPE)
UL LISTED TRANSITION DUCT
(IF NEEDED.)
4" COVER PLATE (IF NEEDED)
(KIT WE1M454)
WARNING RISK OF FIRE
• To reduce the risk of severe injury or death, follow all installation instructions.
$SSOLDQFHLQVWDOODWLRQPXVWEHSHUIRUPHGE\DTXDOL¿HGLQVWDOOHU
Install the clothes appliance according to these instructions and in accordance with local
codes. In the absence of local codes, installation must comply with National Fuel Gas Code,
ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane Installation Code, CSA B149.1.
California Safe Drinking Water and Toxic Enforcement Act.
This act requires the governor of California to publish a list of substances known to the
state to cause cancer, birth defects or other reproductive harm and requires businesses
to warn customers of potential exposure to such substances. Gas appliances can
cause minor exposure to four of these substances, namely benzene, carbon monoxide,
formaldehyde and soot, caused primarily by the incomplete combustion of natural gas
or LP fuels. Properly adjusted dryers will minimize incomplete combustion. Exposure to
these substances can be minimized further by properly venting the dryer to the outdoors.
• This appliance must be exhausted to the outdoors.
• Use only 4” rigid metal ducting for exhausting the appliance to the outdoors.
DO NOTLQVWDOODFORWKHVGU\HUZLWKÀH[LEOHSODVWLFGXFWLQJPDWHULDOV,IÀH[LEOHPHWDO
(semi-rigid or foil-type) duct is installed, it must be UL listed and installed in accordance
with the instructions found in “Connecting The Dryer To House Vent” on page 8 of this
manual. Flexible venting materials are known to collapse, be easily crushed, and trap lint.
7KHVHFRQGLWLRQVZLOOREVWUXFWGU\HUDLUÀRZDQGLQFUHDVHWKHULVNRI¿UH
• Do not install or store this appliance in any location where it could be exposed to water
and or weather.
• Save these instructions. (Installers: Be sure to leave these instructions with the customer).
Installation
Instructions
Unitized Gas
Washer/Dryer
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions for
local inspector’s use.
IMPORTANT- Observe all governing
codes and ordinances.
Note to Installer - Be sure to leave these
instructions with the customer.
Note to Customer - Keep these instructions
with your Use and Care Book for future
reference.
• Before the appliance is removed from service
or discarded, remove the washer and dryer
door.
• Inspect the dryer exhaust outlet and straighten
the outlet walls if they are bent.
• Service information and the wiring diagram
are located at the access panel.
• Do not allow children on or in the appliance.
Close supervision of children is necessary
when the appliance is used near children.
• Install the dryer where the temperature is
above 50°F (10°C) for satisfactory operation of
the dryer control system.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
PARTS SUPPLIED
MATERIALS YOU WILL NEED
2 Rubber Washers
2 Stainer Screens/
Rubber Washers
(washers may be in water hoses)
2 Washer Hoses
1 Cable Tie
LEVEL
8" PIPE WRENCH
10" ADJUSTABLE WRENCHES
(x2)
SLIP JOINT PLIERS
FLAT BLADE SCREWDRIVER
TOOLS YOU WILL NEED
1/4” Nutdriver
Questions on Installation? Call: 1-800-GECARES (US) or Visit our Web site at: www.GEAppliances.com (US).
In Canada, call 800-561-3344 or visit www.GEAppliances.ca.
In the state of Massachusetts:
Installation must be performed by
D TXDOL¿HGRU OLFHQVHG FRQWUDFWRU
SOXPEHU RU JDV¿WWHU TXDOL¿HG RU
licensed by the state.
:KHQ XVLQJ EDOOW\SH JDV VKXWRȺ
valves, they shall be T-handle type.
$ÀH[LEOHJDVFRQQHFWRUZKHQXVHG
must not exceed 3 feet.
233D1835P003
31-16727 12-14 GE Printed in Mexico
Vedere la pagina 0
1 2 3 4 5 6 ... 35 36

Sommario

Pagina 1 - Washer/Dryer

EXHAUST HOODFLEXIBLE GAS LINE CONNECTORSOAP SOLUTIONFOR LEAK DETECTIONPIPECOMPOUNDDUCT TAPEGLOVESSAFETY GLASSES4" DIAM METAL ELBOW4" DUCT CL

Pagina 2

Installation Instructions10PLUMBING INFORMATION WATER SUPPLY REQUIREMENTS• HOT AND COLD WATER FAUCETS – Must be within 42” of the appliance water inle

Pagina 3

Installation Instructions1114BATHROOM OR BEDROOM INSTALLATION• The appliance MUST be vented to the outdoors. See EXHAUST INFORMATIONVHFWLRQ• T

Pagina 4

Installation Instructions1215 SERVICINGWARNING- LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND D

Pagina 5

AVERTISSEMENT - RIESQUE D’INCENDIE• Pour réduire les risques de blessures graves ou de mort, suivez les instructions d’installation./·LQVWDOODWLRQG

Pagina 6

Instructions d’Installation 2(WDSH 9pUL¿H]YRWUH,QVWDOODWLRQGH*D]YRLUVHFWLRQEtape 2 Préparez la Zone et l’Echappement pour  O·,QVWDOOD

Pagina 7

Instructions d’Installation 3DIMENSIONS NOMINALES DU PRODUIT 24”74.5”51”VentilationArrivée d’eau arrière Sortie drainage arrière 4.2”23.75”37”*23.75”

Pagina 8

Instructions d’Installation 41 SE PREPARER POUR L’INSTALLATION D’UN NOUVEL APPAREIL DEBRANCHEZ LE GAZENLEVER LES PELUCHES DE L’OUVERTURE D’ECHAPPEMENT

Pagina 9

Instructions d’Installation 5ALIMENTATION DE GAZ• Un rouleau adhésif pour branchement à gaz de 1/8 in., accessible pour des tests de calibrage du bra

Pagina 10 - Installation Instructions

Instructions d’Installation 65INFORMATION CONCERNANT LE BRANCHEMENT ELECTRIQUE4 TEST DE LA FUITE5INFORMATION CONCERNANT LE BRANCHEMENT ELECTRIQUECONDI

Pagina 11

Instructions d’Installation 76 INFORMATION D’ECHAPPEMENT (CONT.)LISTE DE CONTROLE DU SYSTEME D’ECHAPPEMENT CAPUCHON OU GRILLE DU MUR• Protégez la so

Pagina 12

Installation Instructions2Step 1 Verify Your Gas Installation (see section 2).Step 2 Prepare the Area and Exhaust for Installation of appliance (see

Pagina 13 - *D]8QL¿pHV

Instructions d’Installation 8ECHAPPEMENT ARRIERE STANDARD (Ventilé au-dessous du niveau du sol)8METTRE A NIVEAU ET STABILISER VOTRE APPAREILMettre à n

Pagina 14 - Instructions d’Installation

Instructions d’Installation 9FAIRECOUDES FORTEMENT RECOMMANDES NE PAS FAIRENE PAS UTILISER UN CONDUIT TROP LONGNE PAS ECRASER LE CONDUIT AVEC LA MACH

Pagina 15

Instructions d’Installation 10 INFORMATION SUR LA PLOMBERIE CONDITIONS DE L’APPROVISIONEMENT EN EAU• ROBINETS D’EAU CHAUDE ET FROIDE – Ils doive

Pagina 16

Instructions d’Installation 1114INSTALLATION POUR SALLE DE BAIN OU CHAMBRE• L’appareil DOIT être ventilé vers l’extérieur. Voir INFORMATION D’ECHAPPE

Pagina 17

Instructions d’Installation 1215REPARATION AVERTISSEMENT – MARQUEZ TOUS LES FILS AVANT LE DEBRANCHEMENT LORSQUE VOUS EFFECTUEZ UN CONTROLE POUR REPAR

Pagina 18

ADVERTENCIA RIESGO DE INCENDIO$¿QGHUHGXFLUHOULHVJRGHOHVLRQHVJUDYHVRODPXHUWHVLJDWRGDVODVLQVWUXFFLRQHVGHLQVWDODFLyQ/DLQVWDODFLyQ

Pagina 19

Instrucciones de Instalación3DVR9HUL¿TXHVX,QVWDODFLyQGH*DVFRQVXOWHODVHFFLyQ3DVR3UHSDUHHOÈUHD\HO(VFDSHSDUDOD,QVWDODFLyQGHO(

Pagina 20

Instrucciones de InstalaciónDIMENSIONES NOMINALES DEL PRODUCTO DE 24”µµ9HQWLODFLyQ(QWUDGDVGHDJXDWUDVHUD6DOLGDGHGUHQDMHWUDVHUDµµ

Pagina 21

Instrucciones de InstalaciónClaros Minimos para Instalación que no Sea Alcoba o Clóset&ODURVPLQLPRVSDUDVXSHU¿FLHVFRPEXVWLEOHV\DODLUHOLEUH

Pagina 22

Instrucciones de InstalaciónSUMINISTRO DE GAS• 6H GHEH LQVWDODU XQD URVFD FXELHUWD 137 GH µ HQ XQOXJDU DFFHVLEOH HQ HO VXPLQLVWUR

Pagina 23

Installation Instructions324” NOMINAL PRODUCT DIMENSIONS74.5”51”VentDrain outlet (rear)4.2”23.75”37”*23.75”43”51°* Dimension represents door closed in

Pagina 24

Instrucciones de Instalación4 PRUEBA DE FUGA5 INFORMACIÓN SOBRE LA CONEXIÓN ELÉCTRICAREQUISITOS ELÉCTRICOS(VWH HOHFWURGRPpVWLFR GHEHUi VHU SURYLV

Pagina 25 - 6HFDGRUD8QL¿FDGD

Instrucciones de Instalación6 INFORMACIÓN SOBRE EL ESCAPELISTA DE CONTROL DEL SISTEMA DE ESCAPECAMPANA O CAPERUZA DE PARED 7HUPLQDU GH PRGR TXH

Pagina 26 - Instrucciones de Instalación

Instrucciones de InstalaciónESCAPE TRASERO ESTÁNDAR(Ventilación por encima del nivel del piso)8 NIVELACIÓN DE LA SECADORACómo nivelar y estabilizar e

Pagina 27

Instrucciones de Instalación¿QUÉ HACER?&2'2$/7$0(17(5(&20(1'$'2¿QUÉ NO HACER?1286(81$/21*,78'(;&(6,9$'(/

Pagina 28

Instrucciones de InstalaciónCONEXIÓN A INSTALACIONES DE PLOMERÍA6LQRVHHQFXHQWUDLQVWDODGDLQVWDOHODDUDQGHODGHJRPDHQXQH[WUHPRGHODPDQJXH

Pagina 29

Instrucciones de Instalación13 INSTALACIÓN EN ALCOBA O CLOSET6LVHDSUREyODLQVWDODFLyQGHVXHOHFWURGRPpVWLFRHQDOFREDR FOyVHW HVWR ¿JXUDU

Pagina 30

Instrucciones de Instalación15SERVICIO TÉCNICO ADVERTENCIA- ETIQUETE TODOS LOS CABLES ANTES DE LA DESCONEXIÓN CUANDO SE REALICEN CONTROLES DEL SERV

Pagina 31

Installation Instructions4Minimum Clearance Other Than Alcove or Closet InstallationMinimum clearance to combustible surfaces and for air opening are:

Pagina 32

Installation Instructions5GAS SUPPLY• A 1/8-in.National Pipe Taper thread plugged tapping, accessible for test gauge connection, must be installed imm

Pagina 33

Installation Instructions4 LEAK TESTWARNING: NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS.5ELECTRICAL CONNECTION INFORMATIONELECTRICAL REQUIREMENTS7

Pagina 34

Installation Instructions77 EXHAUST CONNECTIONTHIS DRYER COMES READY FOR REAR EXHAUSTING. IF SPACE IS LIMITED, USE THE INSTRUCTIONS IN SECTION 9 TO EX

Pagina 35 - NO INSTALE ESTE

Installation Instructions8STANDARD REAR EXHAUST9HQWHGDERYHÀRRUOHYHO8LEVELING AND STABILIZING YOUR APPLIANCELevel and stabilizing your appliance

Pagina 36

Installation Instructions9EXHAUST TO LEFT OR RIGHT SIDE OF CABINET• For side ducting, remove the knockout (ONLY 1). Rotate elbow sections so that the

Commenti su questo manuale

Nessun commento