GFDN160GJ
GE
®
Series 7.5 Cu. Ft. Capacity Front Load Gas Dryer
Specification Created 3/15
For answers to your Monogram,
®
GE Profile
or GE
®
appliance questions, visit our website
at geappliances.com or call GE Answer Center
®
service, 800.626.2000.
dryEr Exhausting infOrmatiOn – mEtal duCt Only
For complete information, see installation instructions packed with your dryer.
duCting matErials: For best performance, this dryer should be vented with 4"
diameterallrigidmetalexhaustduct.Ifrigidmetalductcannotbeused,thenUL-listed
flexiblemetal(semi-rigid)ductingcanbeused(KitWX08X10077).Inspecialinstallations,
itmaybenecessarytoconnectthedryertothehouseventusingaflexiblemetal(foil-type)
duct.AUL-listedflexiblemetal(foil-type)ductmaybeusedONLYininstallationswhere
rigidmetalorflexiblemetal(semi-rigid)ductingcannotbeusedANDwherea4"diameter
can be maintained throughout the entire length of the transition duct. Please see installation
instructionpackedwithyourdryerforcompleteinstructionswhenusingflexiblemetal(foil
type)ducting.
Exhaust lEngth CalCulatiOn:
1. Determinethenumberof90°turnsneededforyourinstallation.Ifyouexhausttothe
side or bottom of dryer, add one turn.
2. Themaximumlengthof4'rigid(aluminumorgalvanized)ductwhichcanbetoleratedis
shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be
treated as a 90° elbow.
A turn over 45° should be treated as a 90° elbow.
Dryers mustbeexhaustedtotheoutside.
CautiOn: Forpersonalsafetydonotterminateexhaustintoachimney,underany
enclosedhousefloor(crawlspace),orintoanattic,sincetheaccumulatedlintcouldcreate
afirehazardormoisturecouldcausedamage.Neverterminatetheexhaustintoacommon
ductorplenumwithakitchenexhaust,sincethecombinationoflintandgreasecouldcreate
a fire hazard.
Exhaustductsshouldbeterminatedinadamperedwallcaptopreventbackdrafts,bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed down.
fOr mOrE infOrmatiOn On vEnting kits and aCCEssOriEs, plEasE Call 1-800-gE-CarEs.
Best performance
Domestic
dryer models
Maximum length of 4"
dia. rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4"
opening
B
2-1/2"
opening
7.5 cu. ft.
capacity models
gas dryers
0
1
2
3
90 ft.
60 ft.
45 ft.
35 ft.
60 ft.
45 ft.
35 ft.
25 ft.
A
4
B
2-1/2
A
25 ft.15 ft.4
2-1/2
1-3/4
12
3-1/2
Electrical
Connection
Gas Pipe
Connection